DC Regulated Power Supply - How To Use

By Dean Miller


Regularly whenever digital equipment don't function and also work, we may immediately suspect a faulty switch mode power. But have you learnt that defective or shorted components with the motherboard and also main board might cause the power supply to go wrong too?

Switch mode power supply (SMPS) are designed so properly that whenever there is any short circuit occur primarily board the capability supply would shut again off together with totally stop working. If you have no practical experience about troubleshooting switch mode power supply, you may think that the power supply have trouble where in truth the main board is a real trigger of no power problem.

Switch mode power supply have a recently available sense outlet (if you look at UC3842 PWM IC pin 3, it stated I-sense which often mean up-to-date sense) and if there is short circuit with the secondary side (either with secondary diodes and also main board), the prevailing drawn would be increase this also will head the PWM IC to fix generating output to the power fet and for that reason the power would banned. All the following happen in the split with seconds and you don't need to the chance to know if there are actually output voltages with the secondary edge. 540 Watt For Proliant 5000R for a PC.

Some older design of SMPS power supply do not use the PWM IC, but it do enjoy the circuit to help you detect above current pulled and closed itself straight down whenever the idea detects a shorted component with the secondary edge. One good example was the power supply applied to printer. Printers usually have two panels; one was the power supply although other has been main block. If there is any limited circuit in the main board, the capability supply probably would not work. To be able to isolate with where help, one must get rid of the connector with the power give board. Once the supply connector to your main table was removed, you is now able to switch in the printer and check if you have any voltages present at the power give connector. DL360G4p Serial Attached SCSI may be appropriate for you computer.

If there are actually zero voltages measured across all the supply (VCC) hooks then we can conclude that the power supply have problem and put your whole concentration in this power supply board. What if there usually are voltages measured along the connector? Which means that the principal board is causing this no electrical power problem in all probability due for some shorted components in the main board.